<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-05 09-39-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 67 kHz 13906 13,0663
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,4 dBr 4,95 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 67 kHz MIN: 9 kHz % above 76 kHz: 13,0663 Acquired: 2025/05/05 9.38.46 Total samples: 13906 Equivalent time: 0:11:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,7 dBr MIN: 3,4 dBr AVE: 4,95 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2025/05/05 9.38.45) 09.24 09.26 09.28 09.30 09.32 09.34 09.36 09.38 0 2 4 6 Pm [dBr]